Miscroscope Sys

Raman Microscope

Hightlight:
Raman Microscope
Motor Platform 2um
532/785 Raman
Mapping image

For Email Quatation

klaus@jnewtech.com

Phone Quatation:+86-136 0173 6879

  • Introduction

Jump Technology, the micro-Raman system is a Raman system based on the Hamamatsu 11639 CMOS detector. It has super high stability. There are two types of Raman systems, 532nm and 785nm. The Hamamatsu detector has extremely high sensitivity, high-performance stable laser output, and the overall Raman system has >99% spectral stability (actual measurement). It can detect Raman shifts of 200-3000cm-1, and it is a cost-effective and highly stable Raman solution.


1731477707409536 (1).png

Highlights of Micro-Raman System

Based on the Hamamatsu 11639 CMOS detector, whether it is 532 Raman or 785 Raman, the micro-Raman system can provide a Raman solution with super high cost performance and super high stability

1. Spectrometer based on CMOS detector. With the fully imported Japanese Hamamatsu 11639 detector, a more stable and accurate Raman solution can be provided. It is extremely cost-effective.

2. Rack-mounted microscope, 5x, 20x, 50x, 100x, spot size 5um

3. Excellent stability, after preheating for 15 minutes, the spectral stability is >99%

4. Integrated electric platform, electric platform 100mm * 100mm, supports Raman mapping imaging


Advantages of Micro Raman System

Rack-mounted microscope 5x, 20x, 50x100x, spot size 5um

Excellent stability, after preheating for 15 minutes, the laser stability is >99.9%, the spectrometer stability is >99.99%, and the whole machine stability is greater than 99% (8 hours of actual measurement)

Raman shift 200-2800cm-1, Resolution 7cm-1

High-performance Raman laser 532nm or 785nm

Spectral stability of the whole machine >99%

Integration time 1 millisecond-65 seconds

User-defined database, support material composition analysis, support PCA clustering algorithm

Support SDK, easy to integrate into your system



532/785 显微拉曼规格


RAM3-785-500 Raman System

RAM3-532-200 Raman System

Wavelength

790-1000nm

500-720nm

Raman Shift

200-2800 cm-1

200-3200cm-1

Resolution

7cm-1

7cm-1

Resolution(nm)

0.4nm

0.4nm

Laser

785nm +/- 0.1nm

532nm +/- 0.1nm

Laser Power

600mw

100mw (200mw)

Microscope

5X, 20X, 50X, 100X

5X, 20X, 50X, 100X

Light Spot

5um

5um

System Stability

>99.99%

>99.99%

Spectrometer Stability

1pixel / 10degree

1pixel / 10degree

Laser Stability

>99.9%, 

>99.9%, 4小时测量

Raman System Stability

>99% 

>99% 

Integration Time

1ms - 65s

1ms - 65s

Motor Platform

X 300mm,Y 300mm,Z 200mm

X 300mm,Y 300mm,Z 200mm

Motor Accuracy

X-Y 1um

X-Y 1um

Working Time

continue for 6  hours

continue for 6  hours

Mapping

mapping image

mapping image

Slit

25um

25um

Fiber

SMA905

SMA905

Detector

CMOS 2048pixel

CMOS 2048pixel

Probe

build-in

build-in

LED Display

yes

yes

Fiber

100um laser,200um spectrometer

100um laser,200um spectrometer

SNR

600:1

600:1

Application

Chem

Bio

Demision