Contact: WANG
Mobile: +86-138 0199 7980
Email: klaus@jnewtech.com
Address: Boyang Road16, Build23-A Room207, Shanghai
Raman Microscope
- Hightlight:
- Raman Microscope
- Motor Platform 2um
- 532/785 Raman
- Mapping image
For Email Quatation
klaus@jnewtech.com
- Introduction
Jump Technology, the micro-Raman system is a Raman system based on the Hamamatsu 11639 CMOS detector. It has super high stability. There are two types of Raman systems, 532nm and 785nm. The Hamamatsu detector has extremely high sensitivity, high-performance stable laser output, and the overall Raman system has >99% spectral stability (actual measurement). It can detect Raman shifts of 200-3000cm-1, and it is a cost-effective and highly stable Raman solution.
Highlights of Micro-Raman System
Based on the Hamamatsu 11639 CMOS detector, whether it is 532 Raman or 785 Raman, the micro-Raman system can provide a Raman solution with super high cost performance and super high stability
1. Spectrometer based on CMOS detector. With the fully imported Japanese Hamamatsu 11639 detector, a more stable and accurate Raman solution can be provided. It is extremely cost-effective.
2. Rack-mounted microscope, 5x, 20x, 50x, 100x, spot size 5um
3. Excellent stability, after preheating for 15 minutes, the spectral stability is >99%
4. Integrated electric platform, electric platform 100mm * 100mm, supports Raman mapping imaging
Advantages of Micro Raman System
Rack-mounted microscope 5x, 20x, 50x100x, spot size 5um
Excellent stability, after preheating for 15 minutes, the laser stability is >99.9%, the spectrometer stability is >99.99%, and the whole machine stability is greater than 99% (8 hours of actual measurement)
Raman shift 200-2800cm-1, Resolution 7cm-1
High-performance Raman laser 532nm or 785nm
Spectral stability of the whole machine >99%
Integration time 1 millisecond-65 seconds
User-defined database, support material composition analysis, support PCA clustering algorithm
Support SDK, easy to integrate into your system
532/785 显微拉曼规格
RAM3-785-500 Raman System | RAM3-532-200 Raman System | |
Wavelength | 790-1000nm | 500-720nm |
Raman Shift | 200-2800 cm-1 | 200-3200cm-1 |
Resolution | 7cm-1 | 7cm-1 |
Resolution(nm) | 0.4nm | 0.4nm |
Laser | 785nm +/- 0.1nm | 532nm +/- 0.1nm |
Laser Power | 600mw | 100mw (200mw) |
Microscope | 5X, 20X, 50X, 100X | 5X, 20X, 50X, 100X |
Light Spot | 5um | 5um |
System Stability | >99.99% | >99.99% |
Spectrometer Stability | 1pixel / 10degree | 1pixel / 10degree |
Laser Stability | >99.9%, | >99.9%, 4小时测量 |
Raman System Stability | >99% | >99% |
Integration Time | 1ms - 65s | 1ms - 65s |
Motor Platform | X 300mm,Y 300mm,Z 200mm | X 300mm,Y 300mm,Z 200mm |
Motor Accuracy | X-Y 1um | X-Y 1um |
Working Time | continue for 6 hours | continue for 6 hours |
Mapping | mapping image | mapping image |
Slit | 25um | 25um |
Fiber | SMA905 | SMA905 |
Detector | CMOS 2048pixel | CMOS 2048pixel |
Probe | build-in | build-in |
LED Display | yes | yes |
Fiber | 100um laser,200um spectrometer | 100um laser,200um spectrometer |
SNR | 600:1 | 600:1 |
Application | Chem | Bio |
Demision | 220 x 185 x 94 mm | 220 x 185 x 94 mm |